Tavsiya etilgan quvvat darajasi va ilovalar
|
Quvvat oralig'i |
Odatda arizalar |
|
7-50kva |
Uylar, kichik ofislar, telekom zaxira |
|
60-200kva |
Do'konlar, klinikalar, kichik fabrikalar |
|
250-800Kva |
Mehmonxonalar, kasalxonalar, ma'lumotlar markazlari |
|
1000-2500kva |
Korxonalar, kommunal xizmatlar, konchilik |
Texnik shartlar (namunaviy modellar)
|
Model raqami |
Kutish qobiliyati |
Bosh quvvat |
Dvigatel modeli |
Kuchlanishi |
Chastota |
Konfiguratsiya |
|
P30 |
... |
27kva |
1103A-33G |
230/400V |
50 soat |
Silent / ochish |
|
P150 |
150kva |
135kva |
1106A-70TAG2 |
230/400V |
50 soat |
Silent / treyler |
|
P500 |
500kva |
450KVA |
2506a - E15TAG2 |
400/690V |
50 soat |
Kontsentlangan |
|
P2000 |
2000kva |
1800kva |
4016-61TR3 |
400/690V |
50 soat |
Kontsentlangan |
Perkins generator asosiy parametrlarni o'rnatadi
|
0hz, kosf =0.8, 400 / 230V 3p 4w |
Dizel dvigateli |
alternator |
Tashqi o'lchamlar (mm) |
Yalpi vazn (kg) |
||||
|
Model |
Reded quvvat (kV / kva) |
Kutish qudrati (kV / kVA) |
Model |
Quvvat (kw) |
Model |
Reded quvvat (kV / kva) |
||
|
8gf |
8/10 |
8.8/11 |
403A-11G1 |
8 |
Pi044e |
8/10 |
1580x810x930 |
380 |
|
10GF |
10/12.5 |
11/13.8 |
403A-15G1 |
12 |
Pi044f |
10/12.5 |
1580x810x930 |
500 |
|
16GF |
16/20 |
18/22.5 |
404A-22G1 |
18 |
Pi144d |
16/20 |
1580x810x990 |
540 |
|
24gf |
24/30 |
26/32.5 |
1103A-33G |
28 |
Pi144g |
24/30 |
1580x810x1165 |
660 |
|
28GF |
28/35 |
30.8/38.5 |
1103A-33G |
28 |
Pi144h |
28/35 |
1595x810x1150 |
660 |
|
Razil |
32/40 |
35.2/44 |
1103a-33Tg1 |
41 |
Pi144J |
32/40 |
1595x810x1150 |
730 |
|
40GF |
40/50 |
44/55 |
1103a-33Tg1 |
41 |
Uci224d |
40/50 |
1580x810x1165 |
730 |
|
58GF |
58/72.5 |
63.8/80 |
1104A-44TG1 |
58 |
UCI224F |
58/72.5 |
1760x810x1165 |
780 |
|
96GF |
96/120 |
105.6/132 |
1106A-70tg1 |
119 |
Uci274e |
96/120 |
2240x960x1315 |
1030 |
|
112GF |
112/140 |
123.2/154 |
1106A-70tg1 |
119 |
Uci274e |
112/140 |
2190x810x1365 |
1250 |
|
128GF |
128/160 |
140/176 |
1106A-70TAG2 |
130 |
UCI274F |
128/160 |
2240x960x1315 |
1300 |
|
144GF |
144/180 |
158/198 |
1106A-70TAG3 |
157 |
Uci274g |
144/180 |
2345x810x1365 |
1300 |
|
160GF |
160/200 |
176/220 |
1106A-70TAG4 |
174 |
Uci274h |
160/200 |
2240x960x1590 |
1300 |
|
200gf |
200/250 |
220/275 |
1506a - e88tag3 |
228 |
UCD274k |
200/250 |
2430x960x1590 |
2170 |
|
240GF |
240/300 |
264/330 |
1506a - e88tag5 |
273 |
Hci44d |
240/300 |
3030x1120x1800 |
2500 |
|
300GF |
300/375 |
330/412.5 |
2206c - E13TAG3 |
349 |
HCI444F |
300/375 |
3280x1130x1950 |
3300 |
|
360GF |
360/450 |
400/500 |
2506c - e15tag1 |
396 |
Hci544c |
360/450 |
3280x1130x1950 |
3800 |
|
400GF |
400/500 |
440/550 |
2506c - E15TAG2 |
435 |
Hci544c |
400/500 |
3310x1180x1950 |
3940 |
|
500GF |
500/625 |
550/690 |
2806a - E18tag1a |
555 |
HCI544FS |
500/625 |
3380x1500x2100 |
4706 |
|
640GF |
640/800 |
720/900 |
4006-23tag3a |
705 |
Hci634g |
640/800 |
4450x1750x2350 |
4706 |
|
720GF |
720/900 |
792/990 |
4008Tag1a |
767 |
Lvi1634d |
720/900 |
4850x1870x2350 |
7611 |
|
800GF |
800/1000 |
880/1100 |
4008Tag2a |
899 |
HCI634J |
800/1000 |
4760x1995x2330 |
7611 |
|
1000 gf |
1000/1250 |
1100/1375 |
4012-46TWG2A |
1055 |
Pi734a |
1000/1250 |
4900x1860x2350 |
9154 |
|
1200GF |
1200/1500 |
1320/1650 |
4012-46Tag2a |
1267 |
P1734C |
1200/1500 |
4900x1860x2350 |
11580 |
|
1320GF |
1320/1650 |
1452/1815 |
4012-46TAGAG3A |
1440 |
P1734D |
1320/1650 |
4900x1860x2350 |
11580 |
|
1500GF |
1500/1875 |
1650/2062 |
4016tag1a |
1537 |
Pi734e |
1500/1875 |
6800x2780x3500 |
12000 |
|
1600GF |
1600/2000 |
1760/2200 |
4016tag2a |
1766 |
Pi734f |
1600/2000 |
6800x2780x3500 |
12000 |
|
1800GF |
1800/2250 |
1980/2475 |
4016-61TR3 |
1975 |
Pi734g |
1800/2250 |
8000x3120x4400 |
13400 |
Asosiy xususiyatlar
- Haqiqiy perkins dvigatellari tomonidan quvvatlanadi
- 7 kVA-2500kvadan keng quvvat oralig'i
- Yoqilg'i - Samarali, past - emissiya dizayni
- Bir nechta konfiguratsiya: Ochiq, jim, treyler, kontsentlangan
- CE / ISO global bozorlar uchun sertifikatlangan



Issiq teglar: perkins generatorining o'rnatilgan, Xitoy perkins generator etkazib beruvchilari, fabrika