Tavsiya etilgan quvvat oralig'i va ilovalar
|
Quvvat oralig'i |
Odatda arizalar |
|
25-90kva |
Turar joyni zaxiralash, qishloq telekanal maydonlari, kichik do'konlar |
|
100-250kva |
Kasalxonalar, mehmonxonalar, ofis binolari, fermer xo'jaliklari |
|
300-600kva |
Ishlab chiqarish zavodlari, logistika markazlari, sanoat ustaxonalari |
|
800-1200kva |
Ma'lumot markazlari, aeroportlar, katta {- miqdori tijorat majmualari |
|
1500-4125kva |
Elektr stantsiyalari, tog'-kon operatsiyalari, neft va gaz inshootlari, kommunal yordam |
Ochiq turdagi, jim kanopi, {{0} {{0} {{0} {{0} trigrafiyalarda mavjud.
Texnik shartlar (namunaviy modellar)
|
Model raqami |
Kutish qobiliyati |
Bosh quvvat |
Dvigatel modeli |
Kuchlanishi |
Chastota |
Konfiguratsiya |
|
W30 |
... |
27kva |
WP2.3d33e200 |
230/400V |
50 soat |
Silent / ochish |
|
W150 |
150kva |
135kva |
WP6d152e200 |
230/400V |
50 soat |
Silent / treyler |
|
W500 |
500kva |
450KVA |
12M26D660E200 |
230/400V |
50 soat |
Kontsentlangan |
|
W1000 |
1000kva |
900kva |
12M33D1100E200 |
400/690V |
50 soat |
Kontsentlangan |
|
W2000 |
2000kva |
1800kva |
16M33D2100E200 |
400/690V |
50 soat |
Kontsentlangan |
|
W3300 |
3300 kV |
3000 kV |
16M55D3300E200 |
400/690V |
50 soat |
Kontsentlangan |
|
W4125 |
4125kva |
3750kva |
16M55D4125E200 |
400/690V |
50 soat |
Kontsentlangan |
Odatiy 60Hz, yuqori - kuchlanish, parallel operatsiya va masofadan monitoring variantlari mavjud.
Veyii Dizel generatorlarining asosiy xususiyatlari
- Haqiqiy Weyikai dvigatellari- isbotlangan barqarorlik, yuqori samaradorlik va uzoq muddatli hayot.
- Ultra - keng quvvat oralig'i- 25 kVA dan 4125 funtgacha, Mega - miqdori bo'yicha talabalar uchun kichik uchrashuvlar.
- Bardoshli va moslashuvchan konfiguratsiyalar- Ochiq tur, jim kanopi, treyler va kontsentli birliklar.
- Smart boshqaruv variantlari- Integratsiyalashgan Ieap, yoki smartlastrerlar.
- Eksport - Tayyor rozilik- CE / ISO global bozor standartlariga mo'ljallangan.

Harakatga qo'ng'iroq qiling
Bugun biz bilan bog'laning Weyii generatori uchun narxlar, texnik xususiyatlar yoki sozlash tafsilotlarini o'rnating.


Issiq teglar: Weiayn generator set, Xitoy weyii generator etkazib beruvchilar, zavod
Veyii generatorining parametrlari ro'yxati parametrlar jadvali
| Birlik modeli | Chiqish quvvati (kVt) | Elektr toki (a) | Dizel dvigatel turi | Silindrlar soni | Diametri * insult (mm) | Chadval hajmi (l) | Yog 'miqdorini moylash (l) | Yoqilg'i sarfini sarflash tili / kw | Birlik hajmi (mm) l × w × h | Birlik og'irligi kg | |
| Kvant | Kova | ||||||||||
| Weichai kuch Yangchia seriyali | |||||||||||
| 16GF | 16 | 20 | 28.8 | WP2.1d18e2 | 4 | 85*92 | 2.09 | 12 | 235 | 1500*630*1100 | 650 |
| 20GF | 20 | 25 | 36 | WP2.5d22e2 | 4 | 90*100 | 2.54 | 12 | 235 | 1550*630*1150 | 660 |
| 30GF | 30 | 37.5 | 54 | WP3.9d33e2 | 4 | 102*118 | 3.86 | 12 | 235 | 1600*650*1180 | 800 |
| 34GF | 34 | 42.5 | 61.2 | Wp4.3d38e2 | 4 | 105*125 | 4.33 | 12 | 235 | 1600*650*1180 | 800 |
| 40GF | 40 | 50 | 72 | WP4.6d44e2 | 4 | 108*125 | 4.58 | 12 | 235 | 1600*650*1180 | 820 |
| 48GF | 48 | 60 | 86.4 | WP4.1d50e22 | 4 | 105*118 | 4.09 | 12 | 215 | 1700*600*1100 | 900 |
| 58GF | 58 | 72.5 | 104.4 | WP4.3D61E2 | 4 | 108*118 | 4.32 | 12 | 210 | 1800*650*1200 | 950 |
| Weiii kuchini buzish | |||||||||||
| 50GF | 50 | 62.5 | 90 | WP4d66E200 | 4 | 105*130 | 4.5 | 28 | 198 | 1950*950*1340 | 1100 |
| 60GF | 60 | 75 | 108 | WP4d66E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 80GF | 80 | 100 | 144 | WP4d100e200 | 4 | 105*130 | 4.5 | 28 | 198 | 2200*920*1340 | 1250 |
| 90GF | 90 | 112.5 | 162 | WP4d100e200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 90GF | 90 | 112.5 | 162 | WP4d108e200 | 4 | 105*130 | 4.5 | 28 | 198 | 2200*920*1340 | 1250 |
| 100GF | 100 | 125 | 180 | WP4d108e200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 100GF | 100 | 125 | 180 | WP6d132e200 | 6 | 105*130 | 6.75 | 35 | 198 | 2470*930*1450 | 1550 |
| 120GF | 120 | 150 | 216 | WP6d132e200 | 6 | 105*130 | 6.75 | 35 | 198 | ||
| 120GF | 120 | 150 | 216 | WP6d152e200 | 6 | 105*130 | 6.75 | 35 | 198 | 2470*930*1450 | 1620 |
| 132GF | 132 | 165 | 237.6 | WP6d152e200 | 6 | 105*130 | 6.75 | 39 | 198 | ||
| Weiai kuchli ko'k | |||||||||||
| 180GF | 150 | 187.5 | 270 | WP10d200e200 | 6 | 126*130 | 9.726 | 35 | 195 | 2600*950*1400 | 1650 |
| 200gf | 200 | 250 | 360 | WP10d238e200 | 6 | 126*130 | 9.726 | 35 | 195 | 2750*970*1800 | 2100 |
| 240GF | 220 | 275 | 396 | WP10d264e200 | 6 | 126*130 | 9.726 | 35 | 195 | 2800*970*1800 | 2200 |
| 280GF | 250 | 312.5 | 450 | WP12d317E200 | 6 | 126*155 | 11.596 | 38 | 195 | 2850*970*1800 | 2300 |
| 300GF | 300 | 375 | 540 | WP13d385e200 | 6 | 127*165 | 12.54 | 48 | 195 | 2900*970*1800 | 2400 |
| 350GF | 300 | 375 | 540 | WP13d385e200 | 6 | 127*165 | 12.54 | 48 | 195 | 2950*970*1800 | 2500 |
| 400GF | 400 | 500 | 1010 | Whm6160d518 | 6 | 160*200 | 15.9 | 65 | 195 | 3850*1340*1955 | 5700 |
| Weichai kuch | |||||||||||
| 440 gf | 440 | 550 | 792 | 6M26D484E200 | 6 | 150*150 | 15.9 | 65 | 195 | 3500*1500*2000 | 4800 |
| 880GF | 880 | 1100 | 1584 | 12M26D968E200 | 12 | 150*150 | 31.8 | 120 | 195 | 4500*1700*2450 | 8500 |
| 1000 gf | 1000 | 1250 | 1800 | 12M33D1210E200 | 12 | 150*185 | 39.2 | 146 | 210 | 4800*1800*2450 | 9500 |


























